Power Supply: 13,2 V | RF Signal Generator | SSVM Sinad Meter | Audio Generator |
AF Power Meter | AF Distortion Meter | 8 ohm Load |
Step | Setting | Connection | Adjust | Adjust for |
---|---|---|---|---|
1 | RX Sensitivity Mode: Receive Volume: Fully clockwise Squelch: Turn to clockwise Channel: 19 SSG: 27.185 MHz, 1 uV(-107 dBm), AM 30% modulation | Connect RF Signal Generator to external ANT-jack. Connect SSVM Sinad Meter and Distortion Meter across External speaker out jack with 8 ohm dummy load. | T501 T502 T504 T503 | Adjust the parts of tuning circuit with observing AMD (AutomaticDisMeter) indicates 20 dB SINAD in AM-mode, and adjust output level of RF-SSG until speacker output level reaches about 500 mWatt (2.0 Volt) |
2 | RX Sensitivity Mode: Receive Volume: Fully clockwise Squelch: Turn to clockwise Channel: 19 SSG: 27.185 MHz, 1 uV(-107 dBm), AM 30% modulation | Connect RF Signal Generator to external ANT-jack. Connect SSVM Sinad Meter and Distortion Meter across External speaker out jack with 8 ohm dummy load. | T001 | Adjust for maximum indication on SSVM. |
3 | Squelch adjustment Mode: Receive Squelch: Tight Channel: 19 SSG: 27.185 MHz 1 kHz mod., 2,815uV (-47dBm), 30% mod. | Connect RRF SSG to ANT-jack. Connect AF Power Meter and Distortion Meter across ext-speaker with 8 ohm dummy-load | VR501 | At each mode, Adjust the point until the audio appeared on oscilloscope |
4 | Signal meter adjustment Mode: Receive Volume: 500 mWatt Squelch: Counterwise Channel: 19 SSG: 27.185 MHz, 100 uV (-67 dBm), No mod. | Connect RF signalgenerator to external ANT-jack. Connect AF Power meter and Distortion Meter across external speaker jack with 8 ohm dummy load. | VR301 | Adjust so that the 9`th LCD-Bar display on the LCD-meter. |